Branches and cash-handling sites are targeted at the entrance, the cash machine and the glass, using vehicles, tools or both. Ram raids and cash machine attacks depend on a vehicle reaching the frontage. Attacks on the door and glass depend on time, which a stronger frame and glazing can take away.
What usually suits this kind of premises, layer by layer?
| Layer | What usually suits |
|---|---|
| Bollards and barriers | Crash-rated bollards are the first line of defence where a vehicle attack on a cash machine or entrance is a real risk. Specify the test standard, impact speed and foundations, and check underground services. |
| Shutter or grille | High security shutters or grilles close the frontage when the branch is empty. Where your insurer or head office names a rating, we quote a shutter certified to that rating by name. |
| Glazing and frame | Use security glass graded under BS EN 356 for the attack resistance you need, in a frame designed to hold it. Frame and fixings matter as much as the glass, since either can fail first. |
| Doors and locks | Entrance doors and staff doors should be rated for attack and fitted with high-security locking. Airlock or double-door entrances slow an attacker and control who enters. Escape doors must still open from inside. |
| Access control | Staff, cash and back-of-house areas need controlled entry with an audit trail. Records can be personal data, so keep access to them limited. Escape routes must release from inside and on the fire alarm. |
What level of security does a bank or building society frontage need?
The level is usually set by your head office, your insurer or a risk assessment, and we price to the specification you give us. We do not set the standard for you, but we help you check that each layer meets it. The layers are bollards, shutter or grille, glazing, doors and access control.
Where a rating is named, the certificate matters more than the label. A certificate covers the product as tested and installed. Ask the manufacturer what the certificate requires of the installer. Check the LPCB Red Book, now available as RedBookLive, to confirm a certificate. If your policy asks for a listed installer, tell us at the start, because that decides whether we can take the job. Where your insurer asks for it, the shutter must be certified to the rating they name, and we quote for a certified product by name. See LPS 1175 ratings explained.
Can bollards stop a ram raid on a cash machine?
Bollards tested to a vehicle security barrier standard can stop a vehicle at a stated speed and mass, and a standard steel bollard cannot. The current test standard is ISO 22343-1:2023, which replaced PAS 68 and IWA 14-1. Products tested to those older standards are still accepted, so you may see them on a certificate. PAS 170-1 is a lower speed test for a single bollard. The certificate for the product states what it was tested against.
Fitting is as important as the product. Crash-rated bollards need deep, engineered foundations, and the position must be checked for underground services before anything is dug. Anything on the public highway needs the highway authority's permission. We quote a crash-rated bollard by name and list the groundwork separately. Our crash-rated bollards guide explains the options.
What glass is used in banks and cash-handling premises?
Laminated security glass, tested to BS EN 356, is used where attack resistance is needed. The standard grades glass from P1A to P8B, with the higher grades tested against heavier manual attack. Toughened glass is safety glass, not security glass, because it breaks into small pieces rather than holding together.
A laminated pane has a plastic interlayer, normally PVB, bonded between sheets of glass. When struck, the glass cracks and the interlayer holds the pieces in place. The frame, beads and fixings must be strong enough to keep the pane in the opening. We specify the grade you ask for, price the frame and glass together and explain the choice in the quotation. See laminated security glass explained.
Common questions
Do you work to a head office specification?
Yes. Send us the specification, and we price against it line by line and say where our product differs. If a certificate is asked for, we quote a certified product by name and you can check it on the LPCB Red Book. If your policy asks for a listed installer, tell us at the start, because that decides whether we can take the job.
Does a shutter stop a ram raid?
No. A roller shutter resists a person with tools, and it is not designed to stop a vehicle. Bollards tested to ISO 22343-1, PAS 68 or IWA 14-1 are what stop a vehicle, and they need proper foundations and highway permission.
What does LPS 1175 mean for a branch?
LPS 1175 is a security rating scheme for building components. The current issue is 8.2. Issue 8 ratings use a letter for the tool set and a number for minutes of delay, such as C5 or D10, and older ones used SR1 to SR8. The certificate is what matters, so check the Red Book.
Can an airlock entrance be fitted to an existing branch?
Often yes, depending on the space inside and the frame. The survey checks the structure, door swings and escape routes first. Both doors must open from inside in an emergency, and access control must release on the alarm.