Shutter and Shopfront 0800 088 6248 Free survey

Fire-rated shutters in Olton

Layer 2 of 5: shutter or grille

Looking at fire-rated shutters for a property in Olton? We check what is above the opening and what is behind it before we price anything.

From £3,840 inc VAT (£3,200 plus VAT). Guide price, confirmed at survey.

Fire-rated shutters on commercial premises
County
West Midlands
Planning authority
Solihull Council
Police force
West Midlands Police
Postcode area
B92
From Great Barr
About 10 miles
Price
From £3,840 inc VAT (£3,200 plus VAT)

Will fire-rated shutters suit your premises in Olton?

Delivery of the curtain and box needs planning. Tell us when you enquire if your premises are on a pedestrianised street or in a shared service yard, so we can plan the route and the unloading. Send the postcode as well, because Sheldon and Solihull are close to Olton and a town name alone can mislead.

Security is a separate job. A fire shutter is not automatically strong against forced entry. If the same opening needs protecting from attack, we plan a security shutter in addition and check the two do not conflict. Fire exits and escape routes come first. Say so at the first call.

How does the work go in Olton?

Ratings are given in minutes. E 60 means integrity for 60 minutes, EW adds a limit on radiated heat and EI adds insulation. Ask for the test evidence naming the standard, usually BS EN 1634-1 or, on many existing products, BS 476-22, and check the opening size on it matches yours. Keep the evidence with your fire records.

Wall construction matters. The tested detail assumes a certain wall and fixing method, and a shutter fixed into weak or different material may not perform as tested. We check what the wall is made of at survey, wherever in the West Midlands you are, and tell you if it affects the choice.

Planning for an external fire shutter goes to Solihull Council. Councils commonly treat external shutters as a change to how a building looks, and the council decides for your site. Internal fire shutters usually sit outside planning, though building control still has a say. Send the council the box and guide details from your quotation.

What does it cost in Olton?

Fire-rated shutters in Olton: from £3,840 inc VAT (£3,200 plus VAT). That is a guide. The survey fixes the real figure in an itemised quotation, valid for 90 days.

Keep the reference if an incident at your premises has been reported to the fire service or to West Midlands Police. A fire shutter that has operated should be checked before it is relied on again. Ask your insurer what they require for the premises.

Common questions in Olton

How far is Olton from your base?

Olton is about 10 miles from our base in Great Barr, Birmingham. Tell us the postcode when you get in touch and we will confirm the visit.

Does the shutter need mains power to close?

No. Fire shutters close by gravity or a controlled descent device when an alarm or fusible link triggers them. Some products also use power for opening, so we explain how your chosen product works.

Do fire shutters in Olton need planning permission?

Possibly, if external. Councils commonly expect planning permission for external shutters, and Solihull Council decides for your site. Internal fire shutters usually do not. Building control may still be involved.

How often must it be tested?

Agree the routine with your fire risk assessor. The responsible person must keep fire protection in working order under the Fire Safety Order, and a log of tests is good practice. Servicing is a paid visit.

Full details on fire-rated shutters

Want a price in Olton?

Free survey on new installations, a written itemised quotation, and no obligation.