Will fire-rated shutters suit your premises in Harworth?
Every fire shutter needs a testing routine. The responsible person under the Fire Safety Order keeps fire protection in working order, and a log of tests is part of that. Your fire risk assessor will want to see the records. Keep the log where the next person can find it.
Security is a separate job. A fire shutter is not automatically strong against forced entry. If the same opening needs protecting from attack, we plan a security shutter in addition and check the two do not conflict. Fire exits and escape routes come first. Say so at the first call.
What affects the job in Harworth?
The closing path must be clear. Pallets, racking, display stands and parked trolleys in the opening stop a fire shutter from closing. Mark the line on the floor at your premises in Harworth and brief your staff, including new starters. A fire shutter that cannot close is no use when needed.
Existing fire shutter that no longer closes properly? Stop using it as a barrier and have it inspected. Repairs are quoted after inspection, and a visit is paid. Do not disable the release to stop it dropping, because that removes the protection. Tell us what it does when it fails.
Wall construction matters. The tested detail assumes a certain wall and fixing method, and a shutter fixed into weak or different material may not perform as tested. We check what the wall is made of at survey, wherever in Nottinghamshire you are, and tell you if it affects the choice.
What will you pay in Harworth?
Fire-rated shutters in Harworth: from £3,840 inc VAT (£3,200 plus VAT). That is a guide. The survey fixes the real figure in an itemised quotation, valid for 90 days.
Ratings are given in minutes. E 60 means integrity for 60 minutes, EW adds a limit on radiated heat and EI adds insulation. Ask for the test evidence naming the standard, usually BS EN 1634-1 or, on many existing products, BS 476-22, and check the opening size on it matches yours. Keep the evidence with your fire records.
Common questions in Harworth
How far is Harworth from your base?
Harworth is about 69 miles from our base in Great Barr, Birmingham. Tell us the postcode when you get in touch and we will confirm the visit.
Do fire shutters in Harworth need planning permission?
Possibly, if external. Councils commonly expect planning permission for external shutters, and Bassetlaw District Council decides for your site. Internal fire shutters usually do not. Building control may still be involved.
Can you fit fire shutters in Nottinghamshire?
Yes. Nottinghamshire sits within our Midlands coverage. There is no charge to survey a new installation. We send an itemised written quotation valid for 90 days. Installation is arranged at a time that suits you.
Does the shutter need mains power to close?
No. Fire shutters close by gravity or a controlled descent device when an alarm or fusible link triggers them. Some products also use power for opening, so we explain how your chosen product works.