- County
- Nottinghamshire
- Planning authority
- Broxtowe Borough Council
- Police force
- Nottinghamshire Police
- Postcode area
- NG16
- From Great Barr
- About 42 miles
- Price
- From £3,840 inc VAT (£3,200 plus VAT)
Will fire-rated shutters suit your premises in Eastwood?
Linking to the alarm is electrical work. The shutter releases when the alarm panel sends a signal, so the connection must be done and tested. Tell us who maintains your alarm so the work is coordinated and the system is checked together after fitting. Agree who signs it off before the job starts.
Insulation changes the product. A plain fire shutter holds back flames and hot gases, but does not usually stop radiant heat. If people or stock sit close to the opening, your assessor may want an EW or EI classification. It costs more, so decide early.
What should you check in Eastwood?
Planning for an external fire shutter goes to Broxtowe Borough Council. Councils commonly treat external shutters as a change to how a building looks, and the council decides for your site. Internal fire shutters usually sit outside planning, though building control still has a say. Send the council the box and guide details from your quotation.
Security is a separate job. A fire shutter is not automatically strong against forced entry. If the same opening needs protecting from attack, we plan a security shutter in addition and check the two do not conflict. Fire exits and escape routes come first. Say so at the first call.
Closing needs no mains power. Gravity or a controlled descent device brings the curtain down when an alarm or a fusible link triggers it, so a power cut does not stop the closing. We explain how your chosen product behaves when we survey in Eastwood. Ask for the manufacturer's description of the release.
What will you pay in Eastwood?
Fire-rated shutters in Eastwood: from £3,840 inc VAT (£3,200 plus VAT). That is a guide. The survey fixes the real figure in an itemised quotation, valid for 90 days.
Wall construction matters. The tested detail assumes a certain wall and fixing method, and a shutter fixed into weak or different material may not perform as tested. We check what the wall is made of at survey, wherever in Nottinghamshire you are, and tell you if it affects the choice.
What to ask before you book in Eastwood
How far is Eastwood from your base?
Eastwood is about 42 miles from our base in Great Barr, Birmingham. Tell us the postcode when you get in touch and we will confirm the visit.
How often must it be tested?
Agree the routine with your fire risk assessor. The responsible person must keep fire protection in working order under the Fire Safety Order, and a log of tests is good practice. Servicing is a paid visit.
Do fire shutters in Eastwood need planning permission?
Possibly, if external. Councils commonly expect planning permission for external shutters, and Broxtowe Borough Council decides for your site. Internal fire shutters usually do not. Building control may still be involved.
Does the shutter need mains power to close?
No. Fire shutters close by gravity or a controlled descent device when an alarm or fusible link triggers them. Some products also use power for opening, so we explain how your chosen product works.