Will fire-rated shutters suit your premises in Burslem?
Existing fire shutter that no longer closes properly? Stop using it as a barrier and have it inspected. Repairs are quoted after inspection, and a visit is paid. Do not disable the release to stop it dropping, because that removes the protection. Tell us what it does when it fails.
Every fire shutter needs a testing routine. The responsible person under the Fire Safety Order keeps fire protection in working order, and a log of tests is part of that. Your fire risk assessor will want to see the records. Keep the log where the next person can find it.
Main shopping streets in Burslem include Queen Street and Wedgwood Place. Burslem is a pottery town with Victorian civic buildings, a market place and shops along Queen Street. Burslem has a conservation area covering the historic town centre, which can affect what the council will accept on a frontage.
How does the work go in Burslem?
Ratings are given in minutes. E 60 means integrity for 60 minutes, EW adds a limit on radiated heat and EI adds insulation. Ask for the test evidence naming the standard, usually BS EN 1634-1 or, on many existing products, BS 476-22, and check the opening size on it matches yours. Keep the evidence with your fire records.
Premises in Burslem are about 36 miles from Great Barr. For a fire shutter we ask for your fire strategy or assessment before the survey, so we measure against the right requirement. Surveying a new installation costs nothing. Plans of the floor help if you have them.
Planning for an external fire shutter goes to Stoke-on-Trent City Council. Councils commonly treat external shutters as a change to how a building looks, and the council decides for your site. Internal fire shutters usually sit outside planning, though building control still has a say. Send the council the box and guide details from your quotation.
What will you pay in Burslem?
Fire-rated shutters in Burslem: from £3,840 inc VAT (£3,200 plus VAT). That is a guide. The survey fixes the real figure in an itemised quotation, valid for 90 days.
Closing needs no mains power. Gravity or a controlled descent device brings the curtain down when an alarm or a fusible link triggers it, so a power cut does not stop the closing. We explain how your chosen product behaves when we survey in Burslem. Ask for the manufacturer's description of the release.
What to ask before you book in Burslem
How far is Burslem from your base?
Burslem is about 36 miles from our base in Great Barr, Birmingham. Tell us the postcode when you get in touch and we will confirm the visit.
Is a fire shutter also a security shutter?
Not necessarily. A fire shutter is tested to resist fire, not an attack. If you need both, tell us at survey and we specify each requirement and check they work together.
Do fire shutters in Burslem need planning permission?
Possibly, if external. Councils commonly expect planning permission for external shutters, and Stoke-on-Trent City Council decides for your site. Internal fire shutters usually do not. Building control may still be involved.
How often must it be tested?
Agree the routine with your fire risk assessor. The responsible person must keep fire protection in working order under the Fire Safety Order, and a log of tests is good practice. Servicing is a paid visit.